SAROT +filtration+softener+deionizer ihtiyaç duyduğunuz su kalitesine ulaşmanızı sağlar.
Filtration Systems
Filtration systems are used to remove insoluble particles of various sizes, suspended solids, from water.
Arsenic Treatment
Arsenic is one of the most toxic elements that pose a threat to human health. Various methods such as precipitation, ion exchange, coagulation-filtration, membranes, etc., are applied in arsenic removal.
Saka Arıtım engineers carry out arsenic removal projects taking into account factors such as the flow rate of water, the amount of arsenic, desired water quality, ease of operation, expenses, etc.
In filtration systems prepared with the specially designed AS-FE-MN mineral for arsenic removal, the arsenic content in raw water can be brought to TS266 standards, and even values close to zero can be achieved. The water flow rate, arsenic content, and the ratios of other elements are taken into consideration in achieving these values. In cases where a value of exactly 0 is desired in the output water parameter, and in places where arsenic content is high, reverse osmosis systems are designed as a continuation of arsenic filtration.
During treatment, due to the accumulation of pollution load in the arsenic filter’s surface, over time, blockages and even more severe water pollution can occur in the filtration unit. In this case, the filtration systems are cleaned, and the layer accumulated on the filter is removed by supplying water in the reverse direction of filtration, in other words, a backwashing process is applied.
GET A PRICE QUOTE FOR YOUR WATER AND WASTEWATER TREATMENT SYSTEM NEEDS
System Features
Commercial Systems
Factories, hotels, schools, hospitals, dormitories, etc., with an hourly water consumption of less than 5m³, are designed with low-cost systems.
- Filter tanks with an interior of polyethylene, an exterior of fiberglass-wound coil, test pressure 10 bar, operating pressure 6 bar
- Valves with spherical valves
- Backwashing with clean water*
- Backwashing with raw water
- Programmable automatic backwash
- Backwash at a desired time of the day*
- No-bypass during backwash (shutting off the water in the line)
- Yes-bypass during backwash (not shutting off the water in the line)*
- Backwash based on differential pressure*
- Aeration with a blower*
Industrial Systems
These systems are designed for factories, social facilities, rural settlements, neighborhoods, towns, etc., with an hourly water consumption ranging from 5 to 20 m³.
- Filter tanks with an interior of polyethylene, an exterior of fiberglass-wound coil, test pressure 10 bar, operating pressure 6 bar
- Valves with spherical valves
- Octopus diffusers in the lower distribution structure
- Backwashing with clean water*
- Backwashing with raw water
- Programmable automatic backwash
- Backwash at a desired time of the day*
- No-bypass during backwash (cutting off water in the line)
- Yes-bypass during backwash (not cutting off water in the line)*
- Backwash based on differential pressure
- Aeration with a blower*
Mass Systems
These systems are specially designed for factories, city municipalities, and district municipalities with an hourly water consumption of 20 m³ and above, as well as for city mains water usage.
- ST37 carbon steel filter tanks with internal/external epoxy coating, operating pressure 10 bar, design pressure 6 bar
- Low maintenance costs with spherical valves instead of piston valves
- Mushroom diffusers on top of the mirror in the lower distribution structure
- Filling and emptying manholes
- Backwashing with clean water
- Backwashing with raw water
- Programmable automatic backwash
- Backwash at a desired time of the day*
- No-bypass during backwash (cutting off water in the line)
- Yes-bypass during backwash (not cutting off water in the line)
- Backwash based on differential pressure
- Aeration with a blower
- Touch screen and remote controlled automation
- Can be remotely monitored and intervened in the facility, data transferable to SCADA.
Features marked with (*) can be added to the system design according to need or preference.
Valve Filter Systems | |||||
Product Code | Tank | Flow Rate 15m/h | Flow Rate 20m/h | Antrasit (lt) | Quartz (kg) |
SRV-KF-817 | 8×17 | 0,5 | 0,65 | 2 | 6 |
SRV-KF-835 | 8×35 | 0,5 | 0,65 | 7 | 14 |
SRV-KF-1035 | 10×35 | 0,75 | 1 | 10 | 23 |
SRV-KF-1054 | 10×54 | 0,75 | 1 | 15 | 38 |
SRV-KF-1252 | 12×52 | 1 | 1,5 | 20 | 40 |
SRV-KF-1354 | 13×54 | 1,3 | 1,7 | 25 | 50 |
SRV-KF-1465 | 14×65 | 1,5 | 2 | 35 | 70 |
SRV-KF-1665 | 16×65 | 2 | 2,6 | 50 | 100 |
SRV-KF-1865 | 18×65 | 2,5 | 3,3 | 75 | 115 |
SRV-KF-2162 | 21×62 | 3,3 | 4,5 | 85 | 175 |
SRV-KF-2472 | 24×72 | 4,4 | 5,8 | 100 | 225 |
Valve Filter Systems | |||||
Product Code | Tank | Flow Rate 15m/h | Flow Rate 20m/h | Antrasit (lt) | Quartz (kg) |
SRV-KF-1865 | 18×65 | 2,5 | 3,3 | 75 | 115 |
SRV-KF-2162 | 21×62 | 3,3 | 4,5 | 85 | 175 |
SRV-KF-2472 | 24×72 | 4,4 | 5,8 | 100 | 225 |
SRV-KF-3072 | 30×72 | 6,8 | 9 | 125 | 475 |
SRV-KF-3672 | 36×72 | 10 | 13 | 175 | 650 |
SRV-KF-4272 | 42×72 | 13,4 | 18 | 200 | 775 |
Surface Piping Filter Systems | |||||
Product Code | Tank | Flow Rate 20m/h | Flow Rate 30m/h | Antrasit (lt) | Quartz (kg) |
SRY-KF-3072 | 30×72 | 9 | 14 | 125 | 475 |
SRY-KF-3672 | 36×72 | 13 | 24 | 175 | 650 |
SRY-KF-4294 | 42×94 | 18 | 27 | 200 | 775 |
SRY-KF-4894 | 48×94 | 23 | 35 | 300 | 1125 |
SRY-KF-6394 | 63×94 | 40 | 60 | 550 | 2025 |
SRY-KÇ-48100 | 48×100 | 25 | 37 | 350 | 1375 |
SRY-KÇ-63118 | 63×118 | 40 | 60 | 600 | 2375 |
SRY-KÇ-78128 | 78×128 | 63 | 94 | 800 | 3150 |
SRY-KÇ-94134 | 94×134 | 91 | 136 | 1150 | 4525 |